Model |
Output Voltage |
Output Current |
Watt |
STD-12160 |
12.0V |
16.0A |
192W |
Input |
Voltage |
100-240 VAC |
Line Frequency |
50-60Hz |
Current |
2.8A Max. |
Protection |
Internal Primary Current Fuse |
Configuration |
IEC60320 / C14 |
Output |
Load Regulation |
± 5% (Typical) |
Ripple |
3~5% Vp-p Max. for Output Voltage @ Full Load |
Transient Response |
0.5mS for 50% Load Change Typical |
Holdup Time |
10mS @ Full Load |
Protection |
Short Circuit Protection/ Over Voltage Protection/ Over Current
Protection/Over Temperature Protection |
DC Cord |
UL2464 / 16AWG |
Ferrite Core |
No (Optional) |
Safety
Approvals |
|
CB / UL / cUL / FCC / GS / CE / PSE / BSMI / CCC
/ RCM |
Electrical |
Topology |
LLC |
Dielectric Withstand |
3,000 VAC Primary – Secondary |
Leakage Current |
3.5mA @ 3 Pin |
Efficiency |
Engergy Star Level V, ErP Stage 2 & NRCan Certified |
EMI Conduction&Radiation; |
Compliance to EN55022 Class B |
Harmonic Current |
Compliance to EN61000-3-2,3 |
EMS Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11 |
MTBF |
300,000 Calculated Hours at 25°C, by Telcordia SR-332 |
Environmental |
Operaturing Temperature |
0 to +40°C |
Storage Temperature |
-20 to +80°C |
Relative Humidity |
Operating: 20 to 80% RH |
Storage: 10 to 90% RH |
Cooling |
Natural Convection Cooling |
Mechanical |
Case Dimension |
L183 x W81 x H42 (mm) |
Weight |
850g (Ref.) |